CO₂ Incubators for Cell Culture

840-litre Percival CO₂ incubators with an infrared sensor, additive CO₂ to 10%, 2 to 70 °C range and a SCADA/LIMS port, installed and serviced by JKG.
Percival B3600 large-capacity CO2 incubator for cell culture

Large-Capacity CO₂ Incubators for Cell Culture and Microbiology

Percival B-3600 and B-36: 840-litre CO₂ incubators for labs that have outgrown benchtop units. What sets them apart:

  • Capacity: 840 litres on six adjustable shelves, for flasks, roller bottles, bags and screening plates in one controlled space.
  • Infrared CO₂ sensor with additive CO₂ up to 10%, plus additive humidity control.
  • Wide temperature range, 2 to 70 °C, so the same chamber covers cell culture, microbiology and below-ambient work.
  • Data you can defend: a SCADA/LIMS port for recording that supports 21 CFR Part 11 and GMP Annex 11 work.
  • IntellusUltra touchscreen controller with alarms and experiment protection.

One chamber replaces a row of benchtop incubators, with one controller, one set of records and one service contract.

JKG BioScience supplies Percival B-3600 and B-36 large-capacity CO₂ incubators: 840-litre reach-in chambers with six shelves, an infrared CO₂ sensor and the IntellusUltra touchscreen controller. Our own team handles installation, commissioning, training and service.

Typical work
Culture conditions

Typical Conditions for Cell and Microbial Culture

General starting points. Your cell line, medium and protocol set the exact values. Open dishes and multi-well plates need about 90–95% RH to limit evaporation; the B-3600 controls humidity up to 70% RH, so it is best suited to sealed or vented flasks, roller bottles, culture bags and plates kept in humidified boxes.

CultureTemperatureCO₂Notes
Mammalian cell lines (CHO, HEK293, HeLa, Vero)37 °C5%Match CO₂ to the bicarbonate in the medium to hold pH 7.2–7.4; some media are made for 7.5–10%
Primary cells and stem cells37 °C5%Sensitive to temperature and pH swings; keep door openings short
Insect cell lines (Sf9, High Five)26–28 °CNot usually neededNeeds cooling in a warm laboratory; the refrigerated B-3600 holds this range
CO₂-dependent bacteria (e.g. Neisseria, Haemophilus)35–37 °C5–10%Elevated CO₂ improves growth on primary isolation plates
Microbial production of enzymes and antibioticsSet by the organism, often 25–37 °CAs per protocolLarge shelf area holds many flasks or plates per run
Equipment

Percival Large-Capacity CO₂ Incubators

840-litre chamber with six shelves (3 m² work area), 2–70 °C ± 0.5 °C, CO₂ from ambient to 10%, ultrasonic humidifier and dehumidifier controlling up to 70% RH.
The same 840-litre, six-shelf cabinet for warm incubation: 5 °C above ambient to 70 °C ± 0.5 °C, CO₂ to 10%, pan humidifier with automatic water fill.

Infrared CO₂ control

Vaisala GMP251 CARBOCAP infrared sensor, accurate to 0.1% at 5% CO₂. The CO₂ supply shuts off automatically while the door is open.

IntellusUltra controller

10.1-inch touchscreen controlling up to seven parameters at once, with programmable profiles, graphs, alarms and independent high/low temperature safety limits.

SCADA/LIMS connection

A SCADA/LIMS port for recording and tracking data in your own system, supporting 21 CFR Part 11 and GMP Annex 11 work.

Qualification and service

IQ/OQ/PQ documentation as an option, preventive maintenance and AMCs.
Good practice

Keeping Cultures Healthy and Results Repeatable

Verify CO₂ and temperature

Check CO₂ with an independent analyser and temperature with a calibrated probe at installation and at set intervals. A drifting sensor shifts media pH with no visible warning.

Keep contamination out

Use deionised or RO water for humidification, wipe shelves with 70% ethanol, clean spills at once and keep door openings short. The stainless-steel interior can be heat-sterilised between experiments.
Use high-purity CO₂ with a two-stage regulator, and an automatic cylinder changeover where uptime matters. Schedule sensor calibration and preventive maintenance.
Tender and compliance documents

Catalogues and Compliance Documents

Catalogues, datasheets and certificates for purchase files and government tenders. Need a document that is not listed? Ask us.
FAQ

Frequently Asked Questions

Answers to the questions we hear most. Can’t find what you need? Our team will help.

It holds cultures at a set temperature, CO₂ level and humidity. The CO₂ dissolves in the medium and balances its sodium bicarbonate buffer, keeping pH near 7.2–7.4, the range most mammalian cells need. Humidity limits evaporation, which would otherwise concentrate the medium.

Most culture media contain sodium bicarbonate at a level designed for 5% CO₂. Some, such as DMEM with 3.7 g/L bicarbonate, are formulated for around 10%. Setting CO₂ to match the medium keeps the pH correct, which is why the B-3600 and B-36 control CO₂ from ambient up to 10%.

Both have an 840-litre, six-shelf stainless-steel chamber, an infrared CO₂ sensor and the IntellusUltra controller. The B-3600 is refrigerated and runs from 2 to 70 °C, so it holds 37 °C, or lower setpoints such as 27 °C for insect cells, even in a warm laboratory, and it humidifies and dehumidifies actively. The B-36 heats only, from 5 °C above ambient to 70 °C, and uses a pan humidifier.

Open dishes and multi-well plates lose medium quickly unless humidity is around 90–95% RH. The B-3600 controls humidity up to 70% RH, so it suits sealed or vented flasks, roller bottles, culture bags and plates kept in humidified boxes. Tell us your vessels and workload and we will advise.

The IntellusUltra controller has a SCADA/LIMS port for recording and tracking data in your own system, which Percival states supports 21 CFR Part 11 and GMP Annex 11 compliance. JKG offers IQ/OQ/PQ documentation as an option, along with preventive maintenance and AMCs.

JKG BioScience’s own team installs, commissions and services every chamber we supply, and trains your users. We work with laboratories across India and neighbouring countries and usually reply to enquiries within one working day.