Refrigerated Shaking Incubator: MRC LOM-150
The MRC LOM-150 shakes, incubates and refrigerates in one 150-litre cabinet, supplied, installed and serviced by JKG. What sets it apart from an open shaker in a cold room or a heated-only shaking incubator:
- Cooling built in: 0 to 70 °C, so cultures can run below room temperature as well as above it.
- Temperature constancy of ±0.1 °C, from PID control with a PT-100 sensor, and uniformity of ±1 °C at 37 °C.
- Orbital shaking from 20 to 300 rpm on a 25 mm orbit, with 400 rpm as an option.
- Room for working batches: the 480 × 380 mm platform takes twenty 250 ml, twelve 500 ml or six 1-litre flasks.
- Stainless steel inside: an SUS-304 chamber with forced air circulation.
- Shakes, incubates and refrigerates
- 0 to 70 °C
- ±0.1 °C temperature constancy
- 20 to 300 rpm orbital shaking
- 480 × 380 mm platform
- SUS-304 stainless-steel chamber
The LOM-150 and What It Holds
MRC LOM-150
Flask clamps and platforms
MRC LOM-150 Specifications
| Specification | MRC LOM-150 |
|---|---|
| Chamber volume | 150 L |
| Air circulation | Forced |
| Temperature range | 0 to 70 °C |
| Temperature constancy | ±0.1 °C |
| Temperature uniformity | ±1 °C at 37 °C |
| Control and display | PID control, LED display, PT-100 sensor |
| Shaking motion | Orbital, 25 mm |
| Shaking speed | 20 to 300 rpm (400 rpm optional) |
| Platform | Single, 480 × 380 mm |
| Flask capacity | 30 × 125 ml, 20 × 250 ml, 12 × 500 ml, 6 × 1 L, 5 × 2 L, 4 × 3 L, 2 × 4 L or 1 × 5 L |
| Chamber material | SUS-304 stainless steel |
| Refrigeration | 1/4 HP compressor |
| Heater | 900 W |
| Power supply | 110/220 V, 8.5 A |
| Weight | 98 kg |
Specifications as published by MRC. We confirm the exact configuration, platform and clamps in the quotation.
Why Laboratories Choose a Refrigerated Shaking Incubator
Below ambient without a cold room
Aeration and temperature together
Steady temperature
One platform, many vessels
Stainless-steel chamber
Supported locally
Typical Uses
How to Choose a Shaking Incubator
Start with the temperature. If any protocol runs at or below room temperature, such as protein expression at 16 to 20 °C, you need refrigeration: a heated-only shaker can hold a set point only above ambient. Next, add up the flasks in one run and check them against the platform. Twenty 250 ml or six 1-litre flasks fit the LOM-150. Then check the speed and orbit your method specifies. For static incubation without shaking, see our BOD and laboratory incubators.
- Organisms and culture volumes
- Flask sizes and number per run
- Lowest and highest temperature
- Shaking speed your method specifies
- Floor space and power supply
Specifications and Compliance Documents
Catalogues, technical specifications and compliance documents are available on request for institute purchases and tenders.
What is a refrigerated shaking incubator?
An incubator with a shaking platform inside and a refrigeration system as well as a heater. It keeps flask cultures mixing at a set temperature, including temperatures below that of the room.
What temperature range does the LOM-150 cover?
0 to 70 °C, with a temperature constancy of ±0.1 °C and a uniformity of ±1 °C at 37 °C, as published by MRC.
How many flasks does it hold?
With the matching clamps, the 480 × 380 mm platform takes thirty 125 ml, twenty 250 ml, twelve 500 ml, six 1-litre, five 2-litre, four 3-litre or two 4-litre flasks, or one 5-litre flask.
What shaking speed and orbit does it have?
Orbital shaking from 20 to 300 rpm on a 25 mm orbit. MRC lists 400 rpm as an option.
Do you install and service it?
Yes. JKG engineers install the incubator, train your users, and provide maintenance, breakdown support and spare parts.