Applications

Plant Physiology Research

Plant physiology research equipment: controlled growth chambers plus PlantArray water-use phenotyping and PSI chlorophyll fluorescence for drought, heat, salinity and photosynthesis studies.
Plant-DiTech PlantArray gravimetric phenotyping units with potted plants in a greenhouse

Plant Physiology Research: Controlled Conditions and Precise Measurement

Plant physiology explains how plants capture light, use water and respond to stress. Two things decide the quality of a physiology experiment: how tightly the growing conditions are controlled, and how directly the trait of interest is measured. Get either wrong and real differences between genotypes or treatments disappear into noise.
Common questions include how photosynthesis responds to heat, cold or high light; how quickly stomata close as soil dries; how much water a genotype uses per gram of biomass; and how salinity or flooding alter growth. Each needs defined light, temperature, humidity and root-zone conditions, and instruments that measure the response without disturbing the plant.
JKG BioScience combines both halves: plant growth chambers and walk-in rooms that hold conditions, and phenotyping and photosynthesis instruments from Plant-DiTech and PSI that measure what the plants do.
Typical studies
Measurement

Key Physiological Traits and How to Measure Them

TraitWhat it tells youHow it is measured
Photosystem II efficiency (Fv/Fm, QY)Health of the photosynthetic apparatus; falls under heat, cold, drought, salinity and high lightChlorophyll fluorometer such as PSI FluorPen, or FluorCam imaging
OJIP transient and quenching (NPQ)Where stress affects electron transport and how plants dissipate excess lightFluorPen or FluorCam protocols
Transpiration and water useHow much water each plant uses, hour by hourGravimetric lysimeters such as Plant-DiTech PlantArray
Water-use efficiencyBiomass gained per unit of water usedPlantArray with SPAC-Analytics
Canopy stomatal conductanceHow stomata respond to soil drying, VPD and lightCalculated from PlantArray transpiration and atmospheric data
Reflectance indices (NDVI, PRI)Vigour, chlorophyll content and photosynthetic stressPSI PlantPen
Light received (PAR, spectrum)What the plant actually experiencedPSI SpectraPen quantum and spectral meters
Conditions

Controlling the Environment for Physiology

Set intensity and photoperiod, and measure PAR at plant height. Dimmable LED tiers let you run light-response experiments in one chamber.
Heat and cold studies need fast, stable set points with lights on and off, and ramps that resemble natural days.

Humidity and VPD

Control humidity to set the evaporative demand that drives transpiration and stomatal responses.

CO₂

Elevated CO₂ changes photosynthesis and water use; specify CO₂ control for climate studies.
Keep substrate, pot size and irrigation identical across treatments, or control them plant by plant with PlantArray.

Replication

Spread treatments across chambers or runs so that chamber effects are not mistaken for treatment effects.
Equipment

Recommended Equipment for Plant Physiology

Gravimetric phenotyping for transpiration, water-use efficiency and biomass gain, with plant-by-plant irrigation.
Chlorophyll fluorescence for photosystem II efficiency, OJIP and quenching.
Multi-application chambers with ±0.5 °C stability and options for humidity and CO₂.
Space for PlantArray layouts and large populations under one condition.
SciBrite multi-colour LEDs, each colour dimmable, for light-quality physiology.
Full details of the phenotyping instruments we supply.
Tender and compliance documents

Catalogues and Compliance Documents

Catalogues, datasheets and certificates for purchase files and government tenders. Need a document that is not listed? Ask us.
FAQ

Frequently Asked Questions

Answers to the questions we hear most. Can’t find what you need? Our team will help.

Photosynthesis, transpiration and stomatal behaviour respond within minutes to light, temperature and humidity. A chamber holds those conditions constant, so differences between genotypes or treatments are real rather than weather-driven.

VPD combines temperature and humidity into the drying power of the air. It drives transpiration and stomatal closure, so drought and heat experiments should control or at least record it. Chambers with humidity control let you set VPD rather than just temperature.

Yes. Plant-DiTech PlantArray places each plant on its own load-cell lysimeter and records weight continuously, giving transpiration, water-use efficiency and biomass gain per plant. See Plant-DiTech.

FluorPen for quick single-leaf readings in the lab, greenhouse or field; FluorCam to image fluorescence across whole leaves or plants and follow how stress spreads. See PSI.

Yes. PlantArray suits growth rooms and greenhouses, and PSI instruments are portable. Tell us your space and pot size and we will plan the layout.

Hold soil water at a defined level for each plant rather than withholding water for a fixed number of days. PlantArray controls irrigation plant by plant to do this.

Other plant science applications

Request a Quotation

Tell us what you need and we will reply with a recommendation and quotation, usually within one working day.

Prefer to talk?
Call +91 99682 35954
Email info@jkgbioscience.com

Let's Build Your Research Setup

Tell Us About Your Requirement

Share your application and requirements, and our team will help you identify suitable equipment.