Products

Laboratory Autoclaves & Microbiology Equipment

Microbiology and cell culture equipment for research labs in India: TOMY laboratory autoclaves, Percival CO₂ and BOD incubators, anaerobic and hypoxia chambers, centrifuges, mixers and air samplers.
Streaking a Petri dish beside an autoclave basket and culture flasks

Microbiology and Cell Culture Equipment for Research Laboratories

Microbiology and cell culture work depends on reliable sterilisation, stable incubation and controlled atmospheres. JKG BioScience supplies microbiology lab equipment in India: TOMY vertical autoclaves and centrifuges, Percival CO₂, BOD and mycology incubators, and MRC anaerobic chambers and jars, hypoxia chambers, mixers and microbial air samplers. We supply and service this equipment in India and neighbouring countries, including Bangladesh, Nepal, Sri Lanka and Bhutan.
Every item is supplied with installation, training and service, so a new or expanding laboratory can work with one team for its sterilisation, incubation and culture equipment.
Equipment in this category
Product families

Microbiology Lab Equipment We Supply

TOMY SX-500U (50 L) and SX-700U (69 L) vertical autoclaves with sterilising, dissolving and warming cycles and no plumbing.

Centrifuges (TOMY)

The full TOMY range: MDX refrigerated microcentrifuges (15,000 rpm, −9 °C), Suprema high-speed models up to 60,110 ×g, CAX/AX/NIX low-speed refrigerated, LCX benchtop and Wonder Spin minis.

CO₂ incubators (Percival)

Percival B-36 and B-3600 with temperature, humidity and CO₂ control, heat sterilisation and a stainless-steel antimicrobial interior.

BOD and mycology incubators (Percival)

I-series incubators with IncuWhite LEDs for BOD determination, bacterial culture and germination, and the M-36VL for fungal cultures. For shaken cultures, see the MRC LOM-150 refrigerated shaking incubator.

Anaerobic chambers and jars (MRC)

MRC anaerobic glove boxes holding 220 to 800 Petri dishes, the 6-litre ANJR-150 anaerobic jar and a ppm-level oxygen analyser.

Hypoxia chambers (MRC)

Controlled low-oxygen environments for cell biology, cancer and stem-cell research.

Vortex mixers (MRC)

Vortex and laboratory mixers for resuspending cells, mixing reagents and preparing samples.

Microbial air samplers (MRC)

Air samplers that draw a set air volume onto culture media for environmental and cleanroom monitoring.
Featured: TOMY

Laboratory Autoclaves for Microbiology

The TOMY SX-500U and SX-700U are vertical laboratory autoclaves built for everyday microbiology: sterilising media and glassware at 105–135 °C, dissolving agar at 45–104 °C and holding media at 45–95 °C for pouring. Liquid cycles help prevent boil-over, a dual-fan system shortens cooling, and a self-contained reservoir removes the need for plumbing.
SX-500USX-700U
Volume50 L69 L
ChamberØ31.5 × 63.8 cmØ36.0 × 67.5 cm
Sterilising105–135 °C105–135 °C
Weight60 kg72 kg
Controlled atmospheres

CO₂ Incubators and Controlled-Atmosphere Culture

Percival CO₂ incubators maintain precise temperature, humidity and CO₂ for mammalian cell and tissue culture, anaerobic bacterial growth, microbial production of enzymes and antibiotics, and fermentation studies. A SCADA/LIMS port supports data recording for CFR 21 Part 11 or GMP Annex 11.
ModelTiersRelative humidityTemperature (°C)CO₂Volume (m³)Shelf area (m²)Exterior W × D × H (cm)
B-366Off, medium or high5 above ambient to 70 ± 0.5Up to 10%0.8385.1 × 85.4 × 196.1
B-36006Up to 70% at 30 °C2–70 ± 0.5Ambient to 10%0.8385.1 × 85.4 × 196.1

Anaerobic Chambers, Jars and Hypoxia Chambers

MRC anaerobic chambers, anaerobic jars and hypoxia chambers are covered in detail, with models and capacities, on our anaerobic and hypoxia chambers page.
Selection guide

Choosing Microbiology and Cell Culture Equipment

Sterilisation load

Size the autoclave to your largest regular load and tallest vessel, and add liquid cycles for media.

Incubation temperature

Below-ambient work needs a cooled (BOD) incubator; mammalian culture needs CO₂ and humidity control.

Atmosphere

Obligate anaerobes need an anaerobic chamber or jars; low-oxygen cell studies need a hypoxia chamber.

Light

Lighted incubators suit photosynthetic microbes, algae acclimation and germination.

Records and compliance

Data logging, printers and SCADA/LIMS connectivity support validation and GMP documentation.

Space and utilities

Check floor space, power and ventilation; vertical autoclaves need no plumbing.
Tender and compliance documents

Catalogues and Compliance Documents

Catalogues, datasheets and certificates for purchase files and government tenders. Need a document that is not listed? Ask us.
FAQ

Frequently Asked Questions

Answers to the questions we hear most. Can’t find what you need? Our team will help.

For most laboratories a vertical autoclave such as the TOMY SX-500U (50 L) or SX-700U (69 L) handles media, glassware and waste without plumbing. See laboratory autoclaves.

A BOD or cooled incubator controls temperature, often below ambient, for BOD tests, germination and microbial culture. A CO₂ incubator also controls CO₂ and humidity for mammalian cell and tissue culture.

Yes. Tell us your oxygen range, sample volume and workflow and we will recommend suitable anaerobic chambers, anaerobic jars or hypoxia chambers.

Yes. List the equipment you need in one enquiry and we will respond with a combined quotation and installation plan.

Yes. JKG installs, commissions and services the equipment it supplies, with annual maintenance contracts and breakdown support.

Yes. TOMY SX-series vertical autoclaves, such as the SX-500U and SX-700U, run programmed sterilisation cycles for media, glassware and waste, which makes them a practical autoclave for tissue culture and microbiology laboratories. Tell us your typical loads and volumes and we will advise on the chamber size.

Related equipment

Request a Quotation

Tell us what you need and we will reply with a recommendation and quotation, usually within one working day.

Prefer to talk?
Call +91 99682 35954
Email info@jkgbioscience.com

Let's Build Your Research Setup

Tell Us About Your Requirement

Share your application and requirements, and our team will help you identify suitable equipment.